[vc_row][vc_column][vc_column_text]

Test methods marked with “*” sign are within the scope of the accreditation.

[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”812″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541363962462{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F1798 Standard Test Method for Evaluating the Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]According to this standard, the static and fatigue properties of interconnection mechanisms and subassemblies used in spinal arthrodesis implants are determined.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”813″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541364070056{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F1717 Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The static and fatigue testing of spinal implant assemblies in a vertebrectomy model are conducted in the scope of this standard.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”814″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541364164399{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F2077 Test Methods For Intervertebral Body Fusion Devices” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]According to this standard, intervertebral body fusion device assemblies, spinal implants designed to promote arthrodesis at a given spinal motion segment are subjected to static and dynamic tests.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”815″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541364277242{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F2267 Standard Test Method for Measuring Load Induced Subsidence of Intervertebral Body Fusion Device Under Static Axial Compression” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]According to this standard, subsidence of  intervertebral body fusion devices, spinal implants designed to promote arthrodesis at a given spinal motion segment is determined under static axial compression loading.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”972″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1545216467942{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F2706 Standard Test Methods for Occipital-Cervical” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]Static and dynamic mechanical characteristics of different designs of occipital-cervical and occipital-cervical-thoracic spinal implant assemblies are determined within the scope of this standard.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”818″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541364642997{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F2193 Standard Specifications and Test Methods for Components Used in the Surgical Fixation of the Spinal Skeletal System” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]Static and dynamic performance of components used in the surgical fixation of the spinal skeletal system such as rod, screws, plates is determined within the scope of this standard.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”806″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541364507642{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-001″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Test Method for Determining Wear Test

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test is to determine wear resistance of mobile disc prostheses. Tests are conducted for 1 million cycle at the frequency of 5 Hz. Gravimetric wear analysis is made after tests are completed.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”971″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1545216333120{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-007″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Expulsion

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to determine the resistance of spinal cages to expulsion. Tests can be conducted in both anteroposterior and posteroanterior directions. If spinal cage has an expansion or blade mechanism, torsion test can be conducted to determine required torque to expand cage or to stab the blade. After torsion test, expulsion test is conducted.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”806″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541364507642{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-011″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Test Method for Determining Tensile Test Spinal Bands

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to determine tensile strength of spinal fixation bands.[/vc_column_text][/vc_column][/vc_row]