[vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”863″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541499127060{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-023″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Test Method for Suture Anchor

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to determine pullout strength of the suture anchors from bone model[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”806″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541353302476{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-025″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Test Method for Loop Fixation Systems

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to determine tensile strength of suture and bending strength of metallic component of loop fixation systems.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”864″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541499213754{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-027″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Test Methods for Medical Sutures

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to determine tensile strength of the medical sutures.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”806″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541353302476{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”USP 881″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Tensile Strength Test of Surgical Sutures

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to determine the tensile strength of surgical sutures to ensure adequate mechanical performance during clinical use.[/vc_column_text][vc_column_text][/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”806″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541353302476{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”⁠USP 871″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;” margin_design_tab_text=””]

Needle Attachment Test of Surgical Sutures

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to assess the attachment strength between the surgical needle and suture to ensure secure needle–suture integrity.[/vc_column_text][vc_column_text][/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”806″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541353302476{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”USP Monograph” heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Suture Length

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to verify the accuracy and consistency of surgical suture length in accordance with specified requirements.[/vc_column_text][vc_column_text][/vc_column_text][/vc_column][/vc_row]