[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”822″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541420762761{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F 384 Standard Specifications and Test Methods for Metallic Angled Orthopedic Fracture Fixation Devices” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]According to this standard, performance of angled devices used in the surgical internal fixation is determined. Static and dynamic tests are carried out within this scope.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”823″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541420881750{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F 543 Standard Specification and Test Methods for Metallic Medical Bone Screws” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]Measuring mechanical properties of metallic screws used in bone  are determined with methods in this standard.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”824″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541420968802{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F 1541 Standard Specification and Test Methods for External Skeletal Fixation Devices” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]Performance related mechanical properties of external fixation devices are determined with the methods defined by this standard.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”825″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541421070576{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F 382 Standard Specification and Test Method for Metallic Bone Plates” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]Performance related mechanical properties of bone plate used in the surgical internal fixation are determined with the methods defined by this standard.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”826″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541421171639{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F 1264 Standard Specification and Test Methods for Intramedullary Fixation Devices” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]Performance related mechanical properties of intramedullary fixation devices are determined with the methods defined by this standard. In this context, static, dynamic and torsion tests are performed for both nail and locking screws.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”827″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541421277010{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”*ASTM F 2502 Standard Specification and Test Methods for Absorbable Plates and Screws for Internal Fixation Implants” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]Mechanical characterization of bioabsorbable plates and screws used in orthopedic internal fixation is determined within the scope of this standard.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”828″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541421397095{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”ASTM F 564 Standard Specification and Test Methods for Metallic Bone Staples” heading_tag=”h3″ main_heading_color=”#2155a6″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]This standard provide methods for characterization of the design and mechanical function of metalic staples used for internal fixation of the muscular skeletal system. Bending, pull out, dynamic and tissue fixation strength tests are carried out within this scope.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”965″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1545211965266{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-002″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Test Method for Cable and Swage

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]Labiotech PI-002 comprises two test methods. The purpose of the first test method is to determine tensile strength of cables. The purpose of the second test method defined in Labiotech PI-002 is to determine the maximum tensile force that swage can endure.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”806″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1545218403526{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-012″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Test Method for PEEK Screw

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]Labiotech PI-012 specifies torsion and pullout test for PEEK Screw.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”966″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1545211985616{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-013″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Bending Test Method for Fixed Clavicula Plate

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to determine bending properties of clavicula plates fixed to bone model.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”967″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1545212007419{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-014″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Torsion and Pullout Test Methods for Intramedullar Nails with Talon/Claw Mechanism

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]This method specifies torsion and pullout test methods for intramedullary nails with talon/claw mechanism. The purpose of the torsion test is to determine required torque for talons to penetrate bone model. The purpose of the pullout test is to determine axial pullout strength of the nail while its talons are[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”830″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1541421754128{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-018″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Fatigue Test for Schanz Pins

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]Schanz pins of external fixation devices are tested according to ASTM F1541 test standard. However, it is not specified any test method for schanz pins to evaluate their long-term biomechanical performance in ASTM F1541. Labiotech PI-018 specifies fatigue test method for schanz pins.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”968″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1545212029455{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”Labiotech PI-021″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”]

Static Bending Test for Locking Screw

[/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]Test method for locking screws under dynamic loading condition is specified in ASTM F1264. However, it is not specified any test method for static loading condition to determine yield strength of the device. Labiotech PI-021 specifies static bending test for locking screws.[/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”806″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1765967520798{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”ASTM F3690″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to evaluate the mechanical strength and performance of osteosynthesis implants under defined loading conditions.[/vc_column_text][vc_column_text][/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”806″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1765967520798{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”ASTM F3690″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;”][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to evaluate the mechanical strength and performance of osteosynthesis implants under defined loading conditions.[/vc_column_text][vc_column_text][/vc_column_text][/vc_column][/vc_row][vc_row margin_bottom=”50″][vc_column width=”1/6″][vc_single_image image=”806″ img_size=”100×100″ alignment=”center” css=”.vc_custom_1765967520798{margin-bottom: 10px !important;}”][/vc_column][vc_column width=”5/6″][ultimate_heading main_heading=”ASTM F2180″ heading_tag=”h3″ main_heading_color=”#73b955″ alignment=”left” main_heading_style=”font-weight:bold;” main_heading_line_height=”desktop:30px;” sub_heading_margin=”margin-bottom:10px;” margin_design_tab_text=””][/ultimate_heading][vc_separator color=”custom” accent_color=”#2155a6″ css=”.vc_custom_1541352174812{margin-top: 5px !important;margin-bottom: 5px !important;}”][vc_column_text]The purpose of this test method is to evaluate the mechanical strength and performance of osteosynthesis implants under defined loading conditions.[/vc_column_text][vc_column_text][/vc_column_text][/vc_column][/vc_row]